| PUMPS |
|
FI Frame Mounted End Suction Pumps |
 |
 |
Cast iron casing with integrally cast feet enables pump to be bolted
to base for sturdier installation. Allows for back pull without disturbing piping. |
 |
Low-cost, replaceable wear rings protect casing during normal operation. |
 |
Standard ceramic seals promote product flexibility, enabling basic product offering to
meet a wide range of application requirements. |
 |
Dry shaft design ensures shaft is never exposed to system fluid, eliminated need
for expensive corrosion-resistant shaft, and simplifies sleeve and seal remova/reassembly. |
 |
Rear pullout design allows pump to be serviced without disturbing system piping. |
 |
1/4 NPT pressure tapping on suction and discharge connections. |
 |
Easy-to-replace slip-on shaft sleeve facilitates seal maintenance in the field and
lowers long-term maintenance costs. |
 |
Flush seal line tap allows installation of filter to protect seal from particles
present in open systems. |
 |
Top centerline discharge design simplifies piping layouts, reduces piping
strain, and makes the pump self-venting.
|
|
CI Close-Coupled End Suction Pumpss |
 |
 |
Flush seal line taps allow for installation of filter to protect seal from
particles presing in open systems. |
 |
1/4 NPT pressure tapping on suction and discharge connections. |
 |
Standard ceramic seals promote product flexibility, enabling bsaic product offering
to meet a wide range of application requirements. |
 |
Low-cost, replaceable wear rings protect casing during normal operation. |
 |
Top centerline discharge design simplifies piping layouts, reduces piping strain, and
makes pump self-venting. |
 |
Cast-iron casing with intergrally cast feet enables pump to be bolted to a housekeeping
pad for strudier installation and still allow back pullout without disturbing
the piping. |
 |
Dry shaft design ensures shaft is never exposed to system fluids, eliminates need for
expensive corrosion-resistant shaft, and simplifies sleeve and seal removal/reassembly. |
 |
Easy-to-replace slip-on shaft sleeve facilitates seal maintenance in the field and
lowers long-term maintenance cost. |
 |
Rear pullout design allows pump to be serviced without disturbing system piping.
|
|
KV/KS Vertical In-LIne Pumps |
 |
 |
Designed for optimum performance and ease of installation and maintenance.
Ideal for HVAC and industrial applications. |
 |
Flow to 3500 GPM. |
 |
The split coupler design permits changing of the seal without disturbing the
motor of the piping. |
 |
The axial load is hydraulically balanced to increase learing life, better pump
efficiencies, and lower NPSH requirements. |
 |
The recirculating line flushes seal faces and extends seal life. |
 |
Optimum pump efficiency is achieved by close running impeller to casing clearance.
|
|
TA Single Stage Double Suction Horizontal Split Case Pump |
 |
 |
Rugged, heavy-duty casing design allows higher working pressures, provides greater structural
integrity, and reduces the risk of distortion. |
 |
Top half of casing is easily removed for easy service of the rotating unit without
disturbing piping. |
 |
Impeller is designed to assure minimum NPSH and maximum pump efficiency. |
 |
Mechanical seal option reduces shaft lenght and minimizes shaft deflection, thereby
increasing both seal and bearing life. |
 |
Double suction design virtually eliminates axial thrust and reduces bearing loading,
promoting maximum bearing life. |
 |
Low-cost, replaceable wear rings protect casing during normal operation. |
| CARTRIDGE CIRCULATORS |
|
1600 Series In-Line Pumps |
 |
 |
Rugged casing design has maximum operating pressure of 175 psi and a maximum
operating temperature of 3000F. The 1600 Series is offered in cast iron
bronze-fitted construction or all-bronze construction. |
 |
Permanently lubricated long-life bearing cartridge replaces convetional "wick" type
bearing/bracket assembly. Single bearing cartridge services the entire product line. |
 |
One-piece enclosed impeller assures long life and higher pump efficiencies. |
 |
Standard mechanical seal assures maximum flexibility. One seal fits all models;
several materials available. |
 |
Flexible coupler design dampens system sounds and prevents misalignment forces
from affecting pump casing and pump syste. |
 |
Resilient mounted motor ensures quiet, reliable pump operation. |
 |
One bearing cartridge, one seal, and two motor frames fits all pump models, assuring
superior parts flexibility.
|
|
1900 Series In-Line Pumps |
 |
 |
Close coupled compact design is energy efficient and installs anywhere in
the piping layout. |
 |
Self-supporting design allows horizontal or vertical installation. |
 |
Pump and sealed ball bearing motor are maintenance-free. |
 |
REar pullout design and standard motor promote simple, easy service. |
 |
One seal and shaft sleeve fits all models, assuring superior parts flexibility. |
| FLOW MEASUREMENT |
|
Accu-Flo 1/2" - 4" |
 |
 |
New fixed port venture balancing valve. |
 |
Flow measurement independent of stem and ball position. |
 |
Modified venturi flow measurement section ensures precise and consistent differential
pressure readings. |
 |
Positive shut-off ball valve for service work. |
 |
Can be installed in any position. |
 |
Tamper resistant memory stop. |
 |
1/2" - 2" available in sweat and NPT connections. |
 |
2-1/2", 3" and 4" available flanged connections.
|
| PUMP ACCESSORIES |
|
Suction Diffuser |
 |
 |
Provide maximum flow efficiency at the suction side of the pump while
reducing space and fitting requirements. |
 |
Integral flow-straightening device eliminates the need for a long entrance pipe. |
 |
Specifically designed to serve the needs of commercial HVAC and industrial applications.
|
|
Plus One Multi-Purpose Valve |
 |
 |
Performance features include check valve, balancing valve, and flow metering and measurement. |
 |
Service features include a back-seated stem, easily removed clapper, no lubrication
and only one service tool required. |
| TANKS |
|
Air Separator |


 |
 |
ASM 125# construction. |
 |
Stainless steel removable strainer |
 |
3750F maximum operating temperature. |
 |
Optional higher working pressures.
|
|
CA, CAX, CX Expansion Tanks |
 |
Rubber diaphragm or bladder separates air and water, resulting in elimation of air
versus absorption of air into water |
 |
Optional higher working pressures. |
 |
Heavy Duty butyl rubber bladder removes easily for inspection. |
 |
Full acceptance vessel.
|
|
CA Series Expansion Tank |
 |
Heavy duty butyl rubber bladder removes easily for inspection. |
 |
Full acceptance vessel.
|
|
CAX Series Expansion Tank |
 |
Heavy duty butyl rubber bladder removes easily for inspection. |
 |
Limited acceptance for small installations and chilled water applications where
air and fluid volume requirements are minimal. |
 |
Diaphragm tanks within ASME shells are not used, facilitating inspection of the
bladder and eliminating the need for total tank replacement.
|
|
CX Series Expansion Tank |
 |
Heavy duty dutyle rubber diaphragm expansion tank allows permanent separation
of air and water withing ASME designed and constructed pressure vessel. |
 |
Limited acceptance design for use in small heating installations and most chilled
water applications where smaller air volumes and expanced fluid volumes are needed.
|
|
Heat Transfer |
 |
Complete line of heat exchanger shell and tube designs, with U or straight tube. |
 |
All heaters constructed in accordance with ASME. |
 |
Size range: 4" through 30". |
 |
Specialized head configurations and tuve material also available. |
| SYSTEMS |
|
CPV Pressure Booster Systems and HTM Heat Transfer Modules |
 |
Factory pre-packaged module module design reduces installed cost. |
 |
 |
All components factory assembled on heavy quality steel frame. |
 |
Hydrostaticall tested at factory. |
 |
Modules may be modified or customized to application specifications. |
 |
Convenient, responsive single-source service. |
 |
Compact design for easy installation. |
 |
Taco CI or FI pumps with bronze impellers and mechanical (ceramic) seals. |
 |
Individual pump HOA switches and power-on lights. |
 |
A range of optional equipment is available to customize systems for specific applications. |
 |
Available in 50 and 60 HRZ. |